actions class category materials ETIM specific cost property 1 notes 1 notes 2
Cavity wall insulation facade EC003101 null 21.00 5 Limited in insulation thickness Advised to also renovate the window (frames)
Insulating inside the envelope facade EC010879 null 0.00 5 Limited in insulation thickness Advised to also renovate the window (frames)
Insulating outside the envelope with cavity facade EC010879 null 130.00 5 Moisture proofing/drainage Advised to also renovate the window (frames)
Insulating outside the envelope without cavity facade EC010879 null 130.00 5 Moisture proofing/drainage Advised to also renovate the window (frames)
Insulating inside the envelope facade EC010879 null 30.00 5 Limited in insulation thickness null
Insulating the bottom of the crawlspace floor EC010879 null 22.50 5 Moisture proofing Limited in insulation thickness
Insulating against the underside of the existing floor floor EC010879 null 22.50 5 Moisture proofing Limited in insulation thickness
Placing a new floor with insulation floor EC010879 null 0.00 5 Moisture proofing null
New folding roof roof EC010879 EC010567 0.00 5 null null
New roof (flat) with insulation roof EC010879 EC010567 130.00 5 null null
New roof (slanted) with insulation roof EC010879 EC010567 150.00 5 null null
Insulation on top of the existing roof roof EC010879 null 60.00 5 Roof insulation on the outside is best done when you renovate your roof. null
Insulation under the existing roof roof EC010879 null 40.00 5 Moisture proofing Limited in insulation thickness
Insulation in the ceiling/attic floor roof EC010879 null 40.00 5 Moisture proofing Limited in insulation thickness
Glazing with frame windows EC003536 null 820.00 1 When placing new window/door frames attention must be paid to the airtight connection between the frame and the wall and with casement/awning windows between the frame and the glazing. When placing new window/door frames attention must be paid to the airtight connection between the frame and the wall and with casement/awning windows between the frame and the glazing.
Glazing windows EC003188 null 145.00 1 When placing new window/door frames attention must be paid to the airtight connection between the frame and the wall and with casement/awning windows between the frame and the glazing. When placing new window/door frames attention must be paid to the airtight connection between the frame and the wall and with casement/awning windows between the frame and the glazing.
Door (with glazing) with frame windows EC003534 null 1325.00 1 When placing new window/door frames attention must be paid to the airtight connection between the frame and the wall and with casement/awning windows between the frame and the glazing. When placing new window/door frames attention must be paid to the airtight connection between the frame and the wall and with casement/awning windows between the frame and the glazing.
Exhaust-only mechanical ventilation ventilation EC010004 null 3000.00 null Savings of the different ventilation systems vary greatly and heavily depend on the building envelope, both insulation and air-tightness. The better the building�s insulation and airtightness the more energy you will save with (demand controlled) balanced ventilation (with heat recovery) and demand controlled exhaust-only ventilation. Use noise reducing ducts to prevent nuisance from the installation
Supply-only mechanical ventilation ventilation EC010004 null 3000.00 null Savings of the different ventilation systems vary greatly and heavily depend on the building envelope, both insulation and air-tightness. The better the building�s insulation and airtightness the more energy you will save with (demand controlled) balanced ventilation (with heat recovery) and demand controlled exhaust-only ventilation. Use noise reducing ducts to prevent nuisance from the installation
Balanced ventilation ventilation EC010004 null 6000.00 null Savings of the different ventilation systems vary greatly and heavily depend on the building envelope, both insulation and air-tightness. The better the building�s insulation and airtightness the more energy you will save with (demand controlled) balanced ventilation (with heat recovery) and demand controlled exhaust-only ventilation. Use noise reducing ducts to prevent nuisance from the installation
Balanced ventilation with heat recovery (HRV) ventilation EC010004 null 7000.00 null Savings of the different ventilation systems vary greatly and heavily depend on the building envelope, both insulation and air-tightness. The better the building�s insulation and airtightness the more energy you will save with (demand controlled) balanced ventilation (with heat recovery) and demand controlled exhaust-only ventilation. Use noise reducing ducts to prevent nuisance from the installation
Heat pump a/w cooling system EC012035 null 8000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Heat pump w/w cooling system EC011794 null 15000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Hybrid heat pump a/w cooling system EC012035 null 6000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Hybrid heat pump w/w cooling system EC011794 null 15000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Storage boiler (indirect) space heating and tap water EC011392 null 1000.00 0.7 Must be used in combination with other heating sources. null
Storage boiler (direct) (gas) space heating and tap water EC010231 null 2000.00 0.7 null null
Condensing combination boiler (gas) space heating and tap water EC011396 null 1800.00 0.9 null null
Storage boiler (direct) (electric) space heating and tap water EC011391 null 1450.00 0.7 null null
Condensing combination boiler (electric) space heating and tap water EC010082 null 1800.00 0.9 null null
District heating space heating and tap water EC012346 null 1050.00 null null null
Underfloor heating others null null 30.00 null Underfloor heating can only be installed when the home is sufficiently insulated and airtight. null
Wall heating others null null 55.00 null Wall heating can only be installed when the home is sufficiently insulated and airtight. null
Radiators (low temperature) others EC011022 null 25.00 null Low temperature radiators can only be installed when the home is sufficiently insulated and airtight. null
Radiators (high temperature) others EC011022 null 25.00 null null null
Convectors others EC010218 null 40.00 null null null
Air heating space heating and tap water EC011599 null 7500.00 null This system is only possible with balanced ventilation (with heat recovery) null
Heating panels space heating and tap water EC004039 null 80.00 null Heating panels can't be used as the main heating source, they function best when installed in rooms which are not often used. For instance the bathroom. null
Fan coil unit space heating and tap water EC011034 null 0.00 null null null
Heat pump a/w cooling system EC012035 null 8000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Heat pump w/w cooling system EC011794 null 15000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Hybrid heat pump a/w cooling system EC012035 null 6000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Hybrid heat pump w/w cooling system EC011794 null 15000.00 null A heatpump can only be used in homes with sufficient insulation and LTH. null
Night ventilation others null null 3000.00 null null null
Split unit/airco others EC011583 null 1900.00 null null null
Shower heat (recovery) exchanger others EC011710 null 700.00 null null null
Water saving faucets others EC011328 null 175.00 null null null
Water saving showerheads others EC011383 null 250.00 null null null
Dual flush toilet converters others EC011289 null 0.00 null null null
Rainwater system others EC003481 null 4500.00 null null null
Solar collector others EC010595 null 5000.00 null null null
Home battery others EC001757 null 3000.00 null null null
PCM others EC003498 null 0.00 null null null
Windmill others EC002927 null 10000.00 null null null
Solar panels others EC001750 null 170.00 null null null
Floor hatch others null null 0.00 null null null
mailbox others null null 0.00 null null null
Cable/pipe bushings others null null 0.00 null null null
Drainage pipe bushings others null null 0.00 null null null
Nok others null null 0.00 null null null
Duct bushings (facade) others null null 0.00 null null null
Roof to facade connection (flat roof) others null null 0.00 null null null
Duct bushings (roof) others null null 0.00 null null null
Roof to facade connection (slanted roof) others null null 0.00 null null null
Window frame to wall connection others null null 0.00 null null null
Door frame to wall connection others null null 0.00 null null null
Window frame to roof connection others null null 0.00 null null null
Roller shutter others EC003229 null 600.00 null null null
Awning others null null 1200.00 null null null
Room extension others null null 0.00 null null null
Cavity wall insulation others Blown mineral fibre EC003101 13.50 null Limited in insulation thickness Advised to also renovate the window (frames)
Cavity wall insulation others Polystyrene beads or granules EC003101 13.50 null Limited in insulation thickness Advised to also renovate the window (frames)
Cavity wall insulation others Urea formaldehyde foam EC003101 13.50 null Limited in insulation thickness Advised to also renovate the window (frames)
HR+++ glass (triple glazing) others - EC003188 170.00 null Dew on outside of glass
Demand driven exhaust-only mechanical ventilation others - EC010004 1500.00 null Energy savings heavily depend on building airtightness and insulation.
Wall External Coating (WEC) facade wood wool (thermal conductivity ?=0.065 W/mK) EC010879 160.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing wall. (from 10 to 20 cm)
Wall External Coating (WEC) facade glass wool (thermal conductivity ?=0,040 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing wall. (from 10 to 20 cm)
Wall External Coating (WEC) facade XPS (thermal conductivity ?=0,034 W/mK) EC010879 90.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing wall. (from 10 to 20 cm)
Wall External Coating (WEC) facade rock wool (thermal conductivity ?=0,045 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing wall. (from 10 to 20 cm)
Wall External Coating (WEC) facade Expanded Polyiso Rigid Foam stiferite (thermal conductivity ?=0,022 W/mK) EC010879 200.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing wall. (from 3 to 10 cm)
Wall Internal Coating (WIC) facade wood wool (thermal conductivity ?=0.065 W/mK) EC010879 160.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Wall Internal Coating (WIC) facade glass wool (thermal conductivity ?=0,040 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Wall Internal Coating (WIC) facade XPS (thermal conductivity ?=0,034 W/mK) EC010879 90.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Wall Internal Coating (WIC) facade rock wool (thermal conductivity ?=0,045 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Wall Internal Coating (WIC) facade Expanded Polyiso Rigid Foam stiferite (thermal conductivity ?=0,022 W/mK) EC010879 200.00 5 The requirement for U-value of refurbished external wall in Italy depends on 6 climate areas (A to F). Values vary from 0,40W/m2K to 0.26 W/m2K. Due to its thermal properties is applicable even in cold climate areas (D-E-F)
Roof External Coating (REC) roof wood wool (thermal conductivity ?=0.065 W/mK) EC010879 160.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing roof. (from 10 to 20 cm)
Roof External Coating (REC) roof glass wool (thermal conductivity ?=0,040 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing roof. (from 10 to 20 cm)
Roof External Coating (REC) roof XPS (thermal conductivity ?=0,034 W/mK) EC010879 90.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing roof. (from 10 to 20 cm)
Roof External Coating (REC) roof rock wool (thermal conductivity ?=0,045 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing roof. (from 10 to 20 cm)
Roof External Coating (REC) roof Expanded Polyiso Rigid Foam stiferite (thermal conductivity ?=0,022 W/mK) EC010879 200.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. The required thickness of the thermal insulation depends on the structure of the existing roof. (from 3 to 10 cm)
Roof Internal Coating (RIC) roof wood wool (thermal conductivity ?=0.065 W/mK) EC010879 160.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Roof Internal Coating (RIC) roof glass wool (thermal conductivity ?=0,040 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Roof Internal Coating (RIC) roof XPS (thermal conductivity ?=0,034 W/mK) EC010879 90.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Roof Internal Coating (RIC) roof rock wool (thermal conductivity ?=0,045 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. Strictly limited in thickness due to loss of net floor area and usually not applicable in cold climate areas (D-E-F)
Roof Internal Coating (RIC) roof Expanded Polyiso Rigid Foam stiferite (thermal conductivity ?=0,022 W/mK) EC010879 200.00 5 The requirement for U-value of refurbished external roof in Italy depends on 6 climate areas (A to F). Values vary from 0,32W/m2K to 0.22 W/m2K. Due to its thermal properties is applicable even in cold climate areas (D-E-F)
Basement ceiling External Coating (BEC) floor wood wool (thermal conductivity ?=0.065 W/mK) EC010879 160.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Applicable only in case of basement floor on pilotis or basement floor above unheated areas
Basement ceiling External Coating (BEC) floor glass wool (thermal conductivity ?=0,040 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Applicable only in case of basement floor on pilotis or basement floor above unheated areas
Basement ceiling External Coating (BEC) floor XPS (thermal conductivity ?=0,034 W/mK) EC010879 90.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Applicable only in case of basement floor on pilotis or basement floor above unheated areas
Basement ceiling External Coating (BEC) floor rock wool (thermal conductivity ?=0,045 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Applicable only in case of basement floor on pilotis or basement floor above unheated areas
Basement ceiling External Coating (BEC) floor Expanded Polyiso Rigid Foam stiferite (thermal conductivity ?=0,022 W/mK) EC010879 200.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Applicable only in case of basement floor on pilotis or basement floor above unheated areas
Ground Floor Internal Coating (GIC) floor wood wool (thermal conductivity ?=0.065 W/mK) EC010879 160.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Strictly limited in thickness due to loss of ceiling height
Ground Floor Internal Coating (GIC) floor glass wool (thermal conductivity ?=0,040 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Strictly limited in thickness due to loss of ceiling height
Ground Floor Internal Coating (GIC) floor XPS (thermal conductivity ?=0,034 W/mK) EC010879 90.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Strictly limited in thickness due to loss of ceiling height
Ground Floor Internal Coating (GIC) floor rock wool (thermal conductivity ?=0,045 W/mK) EC010879 120.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Strictly limited in thickness due to loss of ceiling height
Ground Floor Internal Coating (GIC) floor Expanded Polyiso Rigid Foam stiferite (thermal conductivity ?=0,022 W/mK) EC010879 200.00 5 The requirement for U-value of refurbished external basement ceiling in Italy depends on 6 climate areas (A to F). Values vary from 0,42W/m2K to 0.28 W/m2K. Strictly limited in thickness due to loss of ceiling height
Windows Changing windows Wood Thermal break frames (TBF) + ARGON FILLED DOUBLE PANE Glazing EC003188 250.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows Wood Thermal break frames (TBF) + ARGON FILLED DOUBLE PANE Glazing (low emissivity coating) EC003188 280.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows Wood Thermal break frames (TBF) + ARGON FILLED triple PANE Glazing (low emissivity coating) EC003188 300.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows PVC Thermal break frames (TBF) + ARGON FILLED DOUBLE PANE Glazing EC003188 250.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows PVC Thermal break frames (TBF) + ARGON FILLED DOUBLE PANE Glazing (low emissivity coating) EC003188 280.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows PVC Thermal break frames (TBF) + ARGON FILLED triple PANE Glazing (low emissivity coating) EC003188 300.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows Metal Thermal break frames (TBF) + ARGON FILLED DOUBLE PANE Glazing EC003188 300.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows Metal Thermal break frames (TBF) + ARGON FILLED DOUBLE PANE Glazing (low emissivity coating) EC003188 330.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Windows Changing windows Metal Thermal break frames (TBF) + ARGON FILLED triple PANE Glazing (low emissivity coating) EC003188 350.00 1 The requirement for U-value of new windows and doorsin Italy depends on 6 climate areas (A to F). Values vary from 3,00W/m2K to 1.00 W/m2K. Advised to also insulate building envelope
Installation of thermostatic radiator valves others 20% reduction on EP EC011022 0.00 null Installation of bypass branch at each radiator is required in case the heating system is one-pipe system. Review of existing balancing valves may be necessary.
Changing of radiators and installation of thermostatic radiator valves others null EC011022 0.00 null Installation of bypass branch at each radiator is required in case the heating system is one-pipe system. Review of existing balancing valves may be necessary.
Condensing combi boiler space heating and tap water 24 kW EC011396 2500.00 0.9 null null
Condensing boiler space heating and tap water 100 kW EC011396 13800.00 0.9 null null
Condensing boiler space heating and tap water 200 kW EC011396 253000.00 0.9 null null
Condensing boiler space heating and tap water 500 kW EC011396 62100.00 0.9 null null
Solar thermal collector space heating and tap water Flat plate solar collector or vacuum tube solar collector. EC010595 0.00 null It is applicable only in case of central DHW supply system. The preheating DHW storage tank must be placed.
Photovoltaic system economic household equipment Polycrystalline or monocrystalline solar cells EC001750 0.00 null The performance of the photovoltaic system should be determined so that there is no overproduction on an annual basis. Flat roof or proper orientation of slooping roof is necessary. Shading of the collectos should be avoided.
Cavity wall insulation facade Blown mineral fibre null 13.50 5 Limited in insulation thickness Advised to also renovate the window (frames)
Cavity wall insulation facade Polystyrene beads or granules null 13.50 5 Limited in insulation thickness Advised to also renovate the window (frames)
Cavity wall insulation facade Urea formaldehyde foam null 13.50 5 Limited in insulation thickness Advised to also renovate the window (frames)
HR+++ glass (triple glazing) windows - null 170.00 1 Dew on outside of glass null
Demand driven exhaust-only mechanical ventilation ventilation - null 1500.00 null Energy savings heavily depend on building airtightness and insulation. null
External insultation - ETICS facade EPS: 4cm; 0,036W/mK; 1,1m2K/W EC010879 54.24 5 Expanded Polystyrene insulation is a lightweight, rigid, closed cell insulation. EPS is available in several compressive strengths to withstand load and back-fill forces. This closed-cell structure provides minimal water absorption and low vapor permanence. null
External insultation - ETICS facade EPS: 8cm; 0,036W/mK; 2,2m2K/W EC010879 60.98 5 Expanded Polystyrene insulation is a lightweight, rigid, closed cell insulation. EPS is available in several compressive strengths to withstand load and back-fill forces. This closed-cell structure provides minimal water absorption and low vapor permanence. null
External insultation - ETICS facade EPS: 12cm; 0,036W/mK; 3,3m2K/W EC010879 67.70 5 Expanded Polystyrene insulation is a lightweight, rigid, closed cell insulation. EPS is available in several compressive strengths to withstand load and back-fill forces. This closed-cell structure provides minimal water absorption and low vapor permanence. null
External insultation - ETICS facade RW: 4cm; 0,040W/mK; 1,0m2K/W EC010879 52.10 5 Rock wool, which is also called mineral wool, comes in easy-to-install batts, similar to fiberglass. But instead of being composed of fluffy glass fibres, rock wool is made of rocks. The unique composition of rock wool produces a high-performing insulation with the following features: Made from natural, sustainable material; Typically contains up to 75 percent recycled content; Retains heat well and traps air, which slows the transfer of heat; Non-combustible and fire resistant to about 750 degrees; Highly water repellent; Excellent sound-deadening properties; Higher insulating value than fiberglass; Long-term performance�rock wool doesn�t degrade over time; Allows moisture to escape (which deters mould and mildew); Dense, firm batts are friction-fit into place; no stapling necessary. null
External insultation - ETICS facade RW: 8cm; 0,040W/mK; 2,0m2K/W EC010879 70.99 5 Rock wool, which is also called mineral wool, comes in easy-to-install batts, similar to fiberglass. But instead of being composed of fluffy glass fibres, rock wool is made of rocks. The unique composition of rock wool produces a high-performing insulation with the following features: Made from natural, sustainable material; Typically contains up to 75 percent recycled content; Retains heat well and traps air, which slows the transfer of heat; Non-combustible and fire resistant to about 750 degrees; Highly water repellent; Excellent sound-deadening properties; Higher insulating value than fiberglass; Long-term performance�rock wool doesn�t degrade over time; Allows moisture to escape (which deters mould and mildew); Dense, firm batts are friction-fit into place; no stapling necessary. null
External insultation - ETICS facade RW: 12cm; 0,040W/mK; 3,0m2K/W EC010879 73.01 5 Rock wool, which is also called mineral wool, comes in easy-to-install batts, similar to fiberglass. But instead of being composed of fluffy glass fibres, rock wool is made of rocks. The unique composition of rock wool produces a high-performing insulation with the following features: Made from natural, sustainable material; Typically contains up to 75 percent recycled content; Retains heat well and traps air, which slows the transfer of heat; Non-combustible and fire resistant to about 750 degrees; Highly water repellent; Excellent sound-deadening properties; Higher insulating value than fiberglass; Long-term performance�rock wool doesn�t degrade over time; Allows moisture to escape (which deters mould and mildew); Dense, firm batts are friction-fit into place; no stapling necessary. null
External insultation - ETICS facade GW: 4cm; 0,034W/mK; 1,2m2K/W EC010879 58.21 5 Glaswool is an insulating material which is formed when glass is converted into thin fibres with thin layers air in between them. It is also known as Fiberglass insulation and is composed of sand and silica. The characteristics of glass wool are: fire resistant till a temperature of 300 degrees; made of natural materials like sand and silica; 80% of the materials used to manufacture glass wool are recyclable materials; very light weight, very good tensile strength properties and very easy to install; prevent any kind of heat loss especially in HVAC ducting systems; very good insulators of sound; used in auditoriums and suspended ceilings, roof insulation; inorganic material which does not allow the growth of any kind of bacteria. null
External insultation - ETICS facade GW: 8cm; 0,034W/mK; 2,4m2K/W EC010879 60.17 5 Glaswool is an insulating material which is formed when glass is converted into thin fibres with thin layers air in between them. It is also known as Fiberglass insulation and is composed of sand and silica. The characteristics of glass wool are: fire resistant till a temperature of 300 degrees; made of natural materials like sand and silica; 80% of the materials used to manufacture glass wool are recyclable materials; very light weight, very good tensile strength properties and very easy to install; prevent any kind of heat loss especially in HVAC ducting systems; very good insulators of sound; used in auditoriums and suspended ceilings, roof insulation; inorganic material which does not allow the growth of any kind of bacteria. null
External insultation - ETICS facade GW: 12cm; 0,034W/mK; 3,5m2K/W EC010879 61.15 5 Glaswool is an insulating material which is formed when glass is converted into thin fibres with thin layers air in between them. It is also known as Fiberglass insulation and is composed of sand and silica. The characteristics of glass wool are: fire resistant till a temperature of 300 degrees; made of natural materials like sand and silica; 80% of the materials used to manufacture glass wool are recyclable materials; very light weight, very good tensile strength properties and very easy to install; prevent any kind of heat loss especially in HVAC ducting systems; very good insulators of sound; used in auditoriums and suspended ceilings, roof insulation; inorganic material which does not allow the growth of any kind of bacteria. null
Ventilated Fa�ade - External insultation facade EPS: 4cm; 0,036W/mK; 1,1m2K/W EC010879 8.20 5 Expanded Polystyrene insulation is a lightweight, rigid, closed cell insulation. EPS is available in several compressive strengths to withstand load and back-fill forces. This closed-cell structure provides minimal water absorption and low vapor permanence. null
Ventilated Fa�ade - External insultation facade EPS: 8cm; 0,036W/mK; 2,2m2K/W EC010879 14.87 5 Expanded Polystyrene insulation is a lightweight, rigid, closed cell insulation. EPS is available in several compressive strengths to withstand load and back-fill forces. This closed-cell structure provides minimal water absorption and low vapor permanence. null
Internal insultation - Panel facade XPS: 3cm; 0,033W/mK; 0,9m2K/W EC010879 9.62 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. Ensure the board product is not stored close to open flames or other ignition sources and avoid volatile organic compounds and chemicals such as solvents
Internal insultation - Panel facade XPS: 5cm; 0,033W/mK; 1,5m2K/W EC010879 14.32 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. Ensure the board product is not stored close to open flames or other ignition sources and avoid volatile organic compounds and chemicals such as solvents
Air Chamber insultation - Foam facade PUR: 3cm; 0,036W/mK; 0,83m2K/W EC003101 9.36 5 Polyurethane Foam Insulation is one of the most innovative and versatile developments in construction and insulation technology in the past few decades, which can be applied with precision almost anywhere, expanding to completely fill gaps and spaces with a long-lasting solid. null
External insulation - Panel facade XPS: 3cm; 0,032W/mK; 0,9m2K/W EC010879 8.15 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. null
External insulation - Panel facade XPS: 5cm; 0,032W/mK; 1,6m2K/W EC010879 10.94 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. null
External insulation - Panel facade XPS: 8cm; 0,032W/mK; 2,5m2K/W EC010879 16.32 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. null
External insulation - Panel facade XPS: 12cm; 0,032W/mK; 3,8m2K/W EC010879 22.85 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. null
External insulation - Panel facade PU Foam: 3cm; 0,028W/mK; 1,1m2K/W EC010879 10.61 5 Because of its light weight, rigid foam insulation boards can be easily installed as cavity insulation; on flat or pitched roofs or as insulated sheeting in timber-framed buildings. Also, depending on building requirements, they can be cut into a variety of shapes and sizes null
External insulation - Panel facade PU Foam: 5cm; 0,028W/mK; 1,8m2K/W EC010879 12.85 5 Because of its light weight, rigid foam insulation boards can be easily installed as cavity insulation; on flat or pitched roofs or as insulated sheeting in timber-framed buildings. Also, depending on building requirements, they can be cut into a variety of shapes and sizes null
External insulation - Panel facade PU Foam: 8cm; 0,028W/mK; 2,9m2K/W EC010879 17.17 5 Because of its light weight, rigid foam insulation boards can be easily installed as cavity insulation; on flat or pitched roofs or as insulated sheeting in timber-framed buildings. Also, depending on building requirements, they can be cut into a variety of shapes and sizes null
External insulation - Panel facade RW: 5cm; 0,035W/mK; 1,4m2K/W EC010879 15.50 5 Rock wool, which is also called mineral wool, comes in easy-to-install batts, similar to fiberglass. But instead of being composed of fluffy glass fibres, rock wool is made of rocks. The unique composition of rock wool produces a high-performing insulation with the following features: Made from natural, sustainable material; Typically contains up to 75 percent recycled content; Retains heat well and traps air, which slows the transfer of heat; Non-combustible and fire resistant to about 750 degrees; Highly water repellent; Excellent sound-deadening properties; Higher insulating value than fiberglass; Long-term performance�rock wool doesn�t degrade over time; Allows moisture to escape (which deters mould and mildew); Dense, firm batts are friction-fit into place; no stapling necessary. null
External insulation - Panel facade RW: 8cm; 0,035W/mK; 2,3m2K/W EC010879 22.91 5 Rock wool, which is also called mineral wool, comes in easy-to-install batts, similar to fiberglass. But instead of being composed of fluffy glass fibres, rock wool is made of rocks. The unique composition of rock wool produces a high-performing insulation with the following features: Made from natural, sustainable material; Typically contains up to 75 percent recycled content; Retains heat well and traps air, which slows the transfer of heat; Non-combustible and fire resistant to about 750 degrees; Highly water repellent; Excellent sound-deadening properties; Higher insulating value than fiberglass; Long-term performance�rock wool doesn�t degrade over time; Allows moisture to escape (which deters mould and mildew); Dense, firm batts are friction-fit into place; no stapling necessary. null
Ventilated roof - external insultation - Panel others XPS: 5cm; 0,033W/mK; 1,5m2K/W EC010879 10.25 null Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. null
Ventilated roof - external insultation - Panel others XPS: 8cm; 0,033W/mK; 2,4m2K/W EC010879 14.45 null Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. null
Ventilated roof - external insultation - Panel others XPS: 12cm; 0,033W/mK; 3,6m2K/W EC010879 17.25 null Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. null
Internal insulation - Panel others RW: 4cm; 0,035W/mK; 1,1m2K/W; emissivity 0,51 EC010879 13.40 null Rock wool, which is also called mineral wool, comes in easy-to-install batts, similar to fiberglass. But instead of being composed of fluffy glass fibres, rock wool is made of rocks. The unique composition of rock wool produces a high-performing insulation with the following features: Made from natural, sustainable material; Typically contains up to 75 percent recycled content; Retains heat well and traps air, which slows the transfer of heat; Non-combustible and fire resistant to about 750 degrees; Highly water repellent; Excellent sound-deadening properties; Higher insulating value than fiberglass; Long-term performance�rock wool doesn�t degrade over time; Allows moisture to escape (which deters mould and mildew); Dense, firm batts are friction-fit into place; no stapling necessary. null
Internal insulation - Foam others Perlite: 2cm; 0,043W/mK; 0,5m2K/W; emissivity 0,51 EC010879 9.29 null Expanded perlite is a white, ultra-lightweight aggregate ranging from a very fine powder to an aggregate with a particle size up to 6mm in size. It is inorganic, inert, neutral in pH, biologically stable and has no asbestos content. It has excellent thermal insulation properties over an extremely wide temperature range from cryogenics at minus 273�C (absolute zero) up to refractory applications at over 1000�C. It also has a highly adsorbent surface and a very low bulk density which makes it an ideal carrier or low cost filler for many compound formulations. Low-E coatings have been developed to minimize the amount of ultraviolet and infrared light that can pass through, and thus, protect the material below.
Internal insulation - Foam others Perlite: 4cm; 0,043W/mK; 0,9m2K/W EC010879 9.29 null Expanded perlite is a white, ultra-lightweight aggregate ranging from a very fine powder to an aggregate with a particle size up to 6mm in size. It is inorganic, inert, neutral in pH, biologically stable and has no asbestos content. It has excellent thermal insulation properties over an extremely wide temperature range from cryogenics at minus 273�C (absolute zero) up to refractory applications at over 1000�C. It also has a highly adsorbent surface and a very low bulk density which makes it an ideal carrier or low cost filler for many compound formulations. null
Internal insulation - Foam others Perlite: 4cm; 0,043W/mK; 0,9m2K/W; emissivity 0,51 EC010879 9.29 null Expanded perlite is a white, ultra-lightweight aggregate ranging from a very fine powder to an aggregate with a particle size up to 6mm in size. It is inorganic, inert, neutral in pH, biologically stable and has no asbestos content. It has excellent thermal insulation properties over an extremely wide temperature range from cryogenics at minus 273�C (absolute zero) up to refractory applications at over 1000�C. It also has a highly adsorbent surface and a very low bulk density which makes it an ideal carrier or low cost filler for many compound formulations. Low-E coatings have been developed to minimize the amount of ultraviolet and infrared light that can pass through, and thus, protect the material below.
Thermal bridges insulation others mineralized wood wool and bound with high-strength cement; 2cm; 0,09W7,K; 0,22m2K/W EC010879 7.97 null null null
Thermal bridges insulation others mineralized wood wool and bound with high-strength cement; 3cm; 0,09W7,K; 0,33m2K/W EC010879 11.32 null null null
Thermal bridges insulation others polystyrene sheet strips extruded foam, rough surface without skin; 3cm; 0,033W/mK; 0,91m2K/W EC010879 8.24 null null null
Internal insulation - Cement floor light-weighted cement based with EPS: 5cm; 0,1W/mK; 0,5m2K/W EC010879 16.15 5 Expanded polystyrene (EPS) concrete (also known as EPScrete, EPS concrete or lightweight concrete) is a form of concrete known for its light weight made from cement and EPS (Expanded Polystyrene). It is a popular material for use in environmentally "green" homes. EPS concrete combines the construction ease of concrete with the thermal and hydro insulation properties of EPS and can be used for a very wide range of application where lighter loads or thermal insulation or both are desired null
Internal insulation - Cement floor light-weighted cement based with EPS: 10cm; 0,1W/mK; 1m2K/W EC010879 29.67 5 Expanded polystyrene (EPS) concrete (also known as EPScrete, EPS concrete or lightweight concrete) is a form of concrete known for its light weight made from cement and EPS (Expanded Polystyrene). It is a popular material for use in environmentally "green" homes. EPS concrete combines the construction ease of concrete with the thermal and hydro insulation properties of EPS and can be used for a very wide range of application where lighter loads or thermal insulation or both are desired null
Internal insulation - Cement floor light-weighted cement based with EPS: 15cm; 0,1W/mK; 1,5m2K/W EC010879 43.19 5 Expanded polystyrene (EPS) concrete (also known as EPScrete, EPS concrete or lightweight concrete) is a form of concrete known for its light weight made from cement and EPS (Expanded Polystyrene). It is a popular material for use in environmentally "green" homes. EPS concrete combines the construction ease of concrete with the thermal and hydro insulation properties of EPS and can be used for a very wide range of application where lighter loads or thermal insulation or both are desired null
Internal insulation - Cement floor light-weighted cement based with Expanded Glass: 5cm; 0,3W/mK; 0,2m2K/W EC010879 22.82 5 Expanded Glass cement is a high-quality product made of recycled glass and is 100 % mineral. Despite its low density, is very resistant to pressure and it not only acts as a thermal insulator but also absorbs sound; it is moisture-resistant, dimensionally stable over the long term, and resistant to fire and chemicals null
Internal insulation - Cement floor light-weighted cement based with Expanded Glass: 10cm; 0,3W/mK; 0,3m2K/W EC010879 36.70 5 Expanded Glass cement is a high-quality product made of recycled glass and is 100 % mineral. Despite its low density, is very resistant to pressure and it not only acts as a thermal insulator but also absorbs sound; it is moisture-resistant, dimensionally stable over the long term, and resistant to fire and chemicals null
Internal insulation - Cement floor light-weighted cement based with Expanded Glass: 15cm; 0,1W/mK; 0,5m2K/W EC010879 36.70 5 Expanded Glass cement is a high-quality product made of recycled glass and is 100 % mineral. Despite its low density, is very resistant to pressure and it not only acts as a thermal insulator but also absorbs sound; it is moisture-resistant, dimensionally stable over the long term, and resistant to fire and chemicals null
Internal insulation - Panel floor XPS or PU Panels: 2cm; 0,028W/mK; 0,71m2K/W EC010879 9.62 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. Because of its light weight, rigid foam insulation boards can be easily installed as cavity insulation; on flat or pitched roofs or as insulated sheeting in timber-framed buildings. Also, depending on building requirements, they can be cut into a variety of shapes and sizes
Internal insulation - Panel floor XPS or PU Panels: 4cm; 0,028W/mK; 1,43m2K/W EC010879 11.99 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. Because of its light weight, rigid foam insulation boards can be easily installed as cavity insulation; on flat or pitched roofs or as insulated sheeting in timber-framed buildings. Also, depending on building requirements, they can be cut into a variety of shapes and sizes
Internal insulation - Panel floor XPS or PU Panels: 6cm; 0,028W/mK; 2,14m2K/W EC010879 16.67 5 Extruded Polystyrene (XPS) is a high performance, water resistant and lightweight board of thermal insulation with high durability and compression resistance; easy to handle and install; strong and versatile. Because of its light weight, rigid foam insulation boards can be easily installed as cavity insulation; on flat or pitched roofs or as insulated sheeting in timber-framed buildings. Also, depending on building requirements, they can be cut into a variety of shapes and sizes
Wooden frames windows null EC003536 145.64 1 null null
Double glazing windows null EC003188 41.83 1 null null
Double glazing windows null EC003188 49.32 1 null null
Shading - Internal sun flow interior roll-up blind with 50mm PVC louvres for a 1x1,5m window null 50.13 null per unit null
Shading - External sun flow exterior venetian blind with 80mm aluminium louvres EC003229 87.86 null per m2 (up tp 6m2 and 2,75m wide) null
Shading - External sun flow monoblock sunshade 6x2,75m EC003229 1335.23 null per unit null
Shading - Internal sun flow roll-up polyester curtain null 56.53 null per m2 null
Window joint system others Soudal Window System null 16.00 null null null
Gas boiler space heating and tap water Wall-mounted gas boiler <= 25 kW; Natural Gas; Efficiency 0,96 EC011396 2415.30 0.96 null null
Gas boiler space heating and tap water Floor-standing gas boiler > 25 kW [INOX]; Natural Gas; Efficiency 0,96 EC011396 3071.97 0.96 null null
Condensing gas boiler space heating and tap water Wall-mounted condensing gas boiler <= 25 kW; Natural Gas; Efficiency 1,05 EC011396 2415.30 0.9 null null
Condensing gas boiler space heating and tap water Floor-standing condensing gas boiler <= 25 kW; Natural Gas; Efficiency 1,05 EC011396 3071.97 0.9 null null
Condensing gas boiler space heating and tap water Floor-standing condensing gas boiler: 100-150 kW; Natural Gas; Efficiency 1,05 EC011396 9702.27 0.9 null null
Condensing gas boiler space heating and tap water Floor-standing condensing gas boiler: 200-250 kW; Natural Gas; Efficiency 1,05 EC011396 18241.71 0.9 null null
Ground Source Heat Pump space heating and tap water GSHP - Ground Source Heat Pump - 100-150kW; Electricity EC011794 64177.04 null null null
Ground Source Heat Pump space heating and tap water GSHP - Ground Source Heat Pump - 200-250kW; Electricity EC011794 111593.42 null null null
Biomass boiler space heating and tap water Biomass boiler; pellets EC003253 2534.40 0.7 null null
Electric boiler - SFH others Electric boiler - SFH; Electricity; Efficiency 0,99 EC010082 2106.02 0.99 null null
air-to-water Electric Heat pump - SFH others air-to-water Electric Heat pump - SFH; Electricity; COP 4,5 EC012035 1150.00 null null null
Aerator others aerator for sinks and bidets (6l/min; 3bar; polished and chromed brass with stainless steel filter) EC010131 10.34 1 per unit null
Aerator others phone type shower with economizer and/or aerator function EC010131 82.83 null per unit null
Air Source Heat Pumps space heating and tap water Electric air-air HP - multisplit <= 15 kW; Electricity; COP 4,5; EER 4 EC012035 3474.94 null null null
Ground Source Heat Pump space heating and tap water GSHP - Ground Source Heat Pump - 100-150kW; Electricity EC011794 64177.04 null null null
Ground Source Heat Pump space heating and tap water GSHP - Ground Source Heat Pump - 200-250kW; Electricity EC011794 111593.42 null null null
Heat Recovery System others null EC010004 3762.00 null null null
Solar thermal others null EC010595 1429.20 null null null
Geothermal Ground-Water System others Ground-Water System (HP - cost per kWt); COP 4,5; SEER 5; SFH; Power Needed 8 kW; soil efficiency 40 W/mK EC011794 11859.25 null null null
Photovoltaic (costs per kWp - from 1 kW up to 7 kWp) electric generator 1-7 kWp EC001750 5708.54 null (costs per kWp - from 1 kW up to 7 kWp) null
Photovoltaic (costs per kWp - from 7 kW up to 20 kWp) electric generator 7-20 kWp EC001750 9658.54 null (costs per kWp - from 7 kW up to 20 kWp) null
External wall thermal insulation facade EPS (thermal conductivity ?=0,039 W/mK), 10 cm thickness EC010879 48.00 5 Recommended changing the windows (if necessary) before thermal insulation of external walls. null
External wall thermal insulation facade EPS (thermal conductivity ?=0,039 W/mK), 20 cm thickness EC010879 60.00 5 Recommended changing the windows (if necessary) before thermal insulation of external walls. null
External wall thermal insulation facade Graphite EPS (thermal conductivity ?=0,031 W/mK), 8 cm thickness EC010879 48.00 5 Recommended changing the windows (if necessary) before thermal insulation of external walls. null
External wall thermal insulation facade Graphite EPS (thermal conductivity ?=0,031 W/mK), 16 cm thickness EC010879 60.00 5 Recommended changing the windows (if necessary) before thermal insulation of external walls. null
External wall thermal insulation facade Fiber insulation (mineral wool, thermal conductivity ?=0,039 W/mK), 10 cm thickness EC010879 56.00 5 Recommended changing the windows (if necessary) before thermal insulation of external walls. null
External wall thermal insulation facade Fiber insulation (mineral wool, thermal conductivity ?=0,039 W/mK), 20 cm thickness EC010879 75.00 5 Recommended changing the windows (if necessary) before thermal insulation of external walls. null
Flat roof thermal insulation roof EPS (thermal conductivity ?=0,039 W/mK); 20 cm insulation thickness was taken into account for determining the specific cost; straight layer structure + new waterproofing EC010879 79.00 5 Straight or reverse layer structure is recommended depending on the state of the existing waterproofing. null
Flat roof thermal insulation roof XPS (thermal conductivity ?=0,037 W/mK); 20 cm insulation thickness was taken into account for determining the specific cost; reverse layer structure EC010879 71.00 5 Straight or reverse layer structure is recommended depending on the state of the existing waterproofing. null
Double-skin flat roof thermal insulation roof Thermal insulation (wool granules) are blown into the air layer between the concrete layers. 25 cm insulation thickness was taken into account for determining the specific cost. EC010879 40.00 5 Double-skin flat roof and its refurbishment is typical in panel buildings in Hungary. null
Attic floor thermal insulation roof Fiber insulation (mineral wool, thermal conductivity ?=0,039 W/mK), 20 cm thickness EC010879 32.00 5 null null
Attic floor thermal insulation roof Fiber insulation (mineral wool, thermal conductivity ?=0,039 W/mK), 30 cm thickness EC010879 48.00 5 null null
Basement ceiling thermal insulation floor Graphite EPS (thermal conductivity ?=0,031 W/mK), 12 cm thermal insulation thickness was taken into account for determining the specific cost. EC010879 40.00 5 null null
Windows, doors changing windows Plastic or wooden frame, triple glazing EC003536 200.00 1 Recommended changing the windows before thermal insulation of external walls. Installation of external shutters are recommended when windows are changing.
Windows, doors changing windows Aluminium frame, triple glazing EC003536 280.00 1 Recommended changing the windows before thermal insulation of external walls. Installation of external shutters are recommended when windows are changing.
Installation of thermostatic radiator valves others null EC011022 0.00 null Installation of bypass branch at each radiator is required in case the heating system is one-pipe system. Review of existing balancing valves may be necessary.
Changing of radiators and installation of thermostatic radiator valves others null EC011022 0.00 null Installation of bypass branch at each radiator is required in case the heating system is one-pipe system. Review of existing balancing valves may be necessary.
Condensing combi boiler space heating and tap water 24 kW EC011396 2200.00 0.9 null null
Condensing boiler space heating and tap water 100 kW EC011396 12000.00 0.9 null null
Condensing boiler space heating and tap water 200 kW EC011396 22000.00 0.9 null null
Condensing boiler space heating and tap water 500 kW EC011396 54000.00 0.9 null null
Solar thermal collector thermal generator Flat plate solar collector or vacuum tube solar collector. EC010595 0.00 null It is applicable only in case of central DHW supply system. The preheating DHW storage tank must be placed.
Photovoltaic system electric generator Polycrystalline or monocrystalline solar cells EC001750 0.00 null In Hungary, the installation of photovoltaic system is recommended for residential buildings with a connection capacity of up to 50 kW. The performance of the photovoltaic system should be determined so that there is no overproduction on an annual basis.